Home

Product

New Energy Products

Solution
GTM6E series electronic molded case circuit breaker
Rated main circuit current
Rated current
The rated voltage
Application
Modular structural design
Can be quickly placed with attachments
Characterized by high breaking ability and reliable performance
Adapt to smart grid networking
It has four remote functions including telemetry, remote signaling, remote control, and remote adjustment through communication interfaces
The current ranges from 12A-800A and is divided into 3 and 4 poles according to the number of poles
Technical specification
GTM6E-125:
GB/T14048.2
IEC60947-2
Shell level (Inm (A)): 125
Operating frequency (Hz): 50
Breaking type: L/M/H
Polarity: 3P4P/3P4P/3P4P
Rated current (In (A)): 12~32, 40~100, 50~125 adjustable
Rated insulation voltage (Ui (V)): 1000
Rated impulse withstand voltage (Uimp (kV)): 8
Rated operating voltage (Ue (V)): AV400/690
Flying arc distance (mm): ≯ 50
Rated ultimate short-circuit breaking capacity (Icu (kA)): 400V: 35/50/70690: 20:20/20
Rated operating short-circuit breaking capacity (Icu (kA)): 400V: 25/35/50690:10/10/10
Rated short-time withstand current (kA/1s): 1.5
Selective category: A
Service life: Mechanical life (times) Maintenance free: 20000/Mechanical life (times) Maintenance available: 40000/Electrical life (times): 8000
Dimensions (mm): Width (W) (3P/4P): 92/122/92/122/92/122, Length (L): 150, Height (H): 113
Installation board hole size (mm): Width (A) (3P/4P): 30/60/30/60/30/60, Length (B): 129, Diameter (φ): 5
Accessory selection
Alarm contact 08: □
Split release 10: □
Auxiliary contact 20: □
Undervoltage release 30: □
Two sets of auxiliary contacts 60: □
Directly rotate handle Z: □
Extended Rotating Handle Z (Extended): □
Electric operating mechanism P (CD2): □
Connection board: □
Rear wiring R: □
Plug in board wiring PR: □
Plug in board front wiring PF: □
Pull out formula:-
MODBUS communication module D: □
GTM6E-250
GB/T14048.2
IEC60947-2  
Shell level (Inm (A)): 250
Operating frequency (Hz): 50
Breaking type: L/M/H
Polarity: 3P4P/3P4P/3P4P
Rated current (In (A)): 100~250 adjustable
Rated insulation voltage (Ui (V)): 100
Rated impulse withstand voltage (Uimp (kV)): 8
Rated operating voltage (Ue (V)): AV400/690
Flying arc distance (mm): ≯ 50
Rated ultimate short-circuit breaking capacity (Icu (kA)): 400V: 35/50/70690: 20:20/20
Rated operating short-circuit breaking capacity (Icu (kA)): 400V: 25/35/50690:10/10/10
Rated short-time withstand current (kA/1s): 3
Selective category: A
Service life: Mechanical life (times) Maintenance free: 20000/Mechanical life (times) Maintenance available: 40000/Electrical life (times): 8000
Dimensions (mm): Width (W) (3P/4P): 104/142/104/142/104/142, Length (L): 165, Height (H): 117
Installation board hole size (mm): Width (A) (3P/4P): 35/70/35/70/35/70, Length (B): 126, Diameter (φ): 5
Accessory selection
Alarm contact 08: □
Split release 10: □
Auxiliary contact 20: □
Undervoltage release 30: □
Two sets of auxiliary contacts 60: □
Directly rotate handle Z: □
Extended Rotating Handle Z (Extended): □
Electric operating mechanism P (CD2): □
Connection board: □
Rear wiring R: □
Plug in board wiring PR: □
Plug in board front wiring PF: □
Pull out formula:-
MODBUS communication module D: □
GTM6E-400:
GB/T14048.2
IEC60947-2
Shell level (Inm (A)): 400
Operating frequency (Hz): 50
Breaking type: L/M/H
Polarity: 3P4P/3P4P/3P4P
Rated current (In (A)): 160~400 adjustable
Rated insulation voltage (Ui (V)): 1000
Rated impulse withstand voltage (Uimp (kV)): 8
Rated operating voltage (Ue (V)): AV400/690
Flying arc distance (mm): ≯ 100
Rated ultimate short-circuit breaking capacity (Icu (kA)): 400V: 50/70/100690: 20:20/20
Rated operating short-circuit breaking capacity (Icu (kA)): 400V: 35/50/70690:15/15/15
Rated short-time withstand current (kA/1s): 5
Selective Category: B
Service life: Mechanical life (times) Maintenance free: 10000/Mechanical life (times) Maintenance available: 20000/Electrical life (times): 7500
Dimensions (mm): Width (W) (3P/4P): 150/198/150/198/150/198, Length (L): 257, Height (H): 150
Installation board hole size (mm): Width (A) (3P/4P): 44/94/44/94/44/94, Length (B): 194, Diameter (φ): 7
Accessory selection
Alarm contact 08: □
Split release 10: □
Auxiliary contact 20: □
Undervoltage release 30: □
Two sets of auxiliary contacts 60: □
Directly rotate handle Z: □
Extended Rotating Handle Z (Extended): □
Electric operating mechanism P (CD2): □
Connection board: □
Rear wiring R: □
Plug in board wiring PR: □
Plug in board front wiring PF: □
Extraction formula: □
MODBUS communication module D: □
GTM6E-630:
GB/T14048.2
IEC60947-2
Shell level (Inm (A)): 630
Operating frequency (Hz): 50
Breaking type: L/M/H
Polarity: 3P4P/3P4P/3P4P
Rated current (In (A)): 250~630 adjustable
Rated insulation voltage (Ui (V)): 1000
Rated impulse withstand voltage (Uimp (kV)): 8
Rated operating voltage (Ue (V)): AV400/690
Flying arc distance (mm): ≯ 100
Rated ultimate short-circuit breaking capacity (Icu (kA)): 400V: 50/70/100690: 20:20/20
Rated operating short-circuit breaking capacity (Icu (kA)): 400V: 35/50/70690:15/15/15
Rated short-time withstand current (kA/1s): 8
Selective Category: B
Service life: Mechanical life (times) Maintenance free: 10000/Mechanical life (times) Maintenance available: 20000/Electrical life (times): 7500
Dimensions (mm): Width (W) (3P/4P): 150/198/150/198/150/198, Length (L): 257, Height (H): 150
Installation board hole size (mm): Width (A) (3P/4P): 44/94/44/94/44/94, Length (B): 194, Diameter (φ): 7
Accessory selection
Alarm contact 08: □
Split release 10: □
Auxiliary contact 20: □
Undervoltage release 30: □
Two sets of auxiliary contacts 60: □
Directly rotate handle Z: □
Extended Rotating Handle Z (Extended): □
Electric operating mechanism P (CD2): □
Connection board: □
Rear wiring R: □
Plug in board wiring PR: □
Plug in board front wiring PF: □
Extraction formula: □
MODBUS communication module D: □
GTM6E-800:
GB/T14048.2
IEC60947-2
Shell level (Inm (A)): 800
Operating frequency (Hz): 50
Breaking type: L/M/H
Polarity: 3P4P/3P4P/3P4P
Rated current (In (A)): 250~630, 320~800 adjustable
Rated insulation voltage (Ui (V)): 1000
Rated impulse withstand voltage (Uimp (kV)): 8
Rated operating voltage (Ue (V)): AV400/690
Flying arc distance (mm): ≯ 100
Rated ultimate short-circuit breaking capacity (Icu (kA)): 400V: 50/70/100690: 20:20/20
Rated operating short-circuit breaking capacity (Icu (kA)): 400V: 35/50/70690:15/15/15
Rated short-time withstand current (kA/1s): 10
Selective Category: B
Service life: Mechanical life (times) Maintenance free: 10000/Mechanical life (times) Maintenance available: 20000/Electrical life (times): 7500
Dimensions (mm): Width (W) (3P/4P): 210/280/210/280/280, Length (L): 280, Height (H): 150
Installation board hole size (mm): Width (A) (3P/4P): 70/140/70/140/70/140, Length (B): 243, Diameter (φ): 7
Accessory selection
Alarm contact 08: □
Split release 10: □
Auxiliary contact 20: □
Undervoltage release 30: □
Two sets of auxiliary contacts 60: □
Directly rotate handle Z: □
Extended Rotating Handle Z (Extended): □
Electric operating mechanism P (CD2): □
Connection board: □
Rear wiring R: □
Plug in board wiring PR: □
Plug in board front wiring PF: □
Extraction formula: □
MODBUS communication module D: □
Download
点击下载 附件:GTM6E电子式塑壳断路器.pdf    大小: 38.18MB 下载:
Leave a message
Under construction...
Committed to technological innovation
Make electricity supply more reliable, make electricity use more secure.
Product quotation consultation
A free consultation
hotline:400 8099 777

CONTACT US

WeChat

Jubang science and technology park, wei16 road, leqing economic development zone, zhejiang province

  • phone:+86577 62799786
  • fax:+86577 62799771
  • Email:jubanggroup@163.com
  • web:www.mccb.cn
  • Customer service hotline:400 8099 777